Suction pressure for 410a

What Determines High Head Pressure. A 410A system who have 400-418 PSIG on the high side, while the lower side is 120-130 PSI. If it is more than this, it is considered high. ... Suction pressure increases; On the suction side, there is fluttering pressure; High head pressure can also cause noises; Condenser piping can have …

Suction pressure for 410a. Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the components that make up Freon™ 407C and Freon™ 410A. Table 1. Components of Freon™ 407C: HFC-32/HFC-125/HFC-134a and Freon™ 410A: HFC-32/HFC-125

Suction pressure control — loss of charge P170AA-400C SPST Open Low 100 470 690 Fan cycling for head P170CA-400C SPST Open High 200 610 690 ... PRESSURE CONTROLS COMPATIBLE WITH R-410A COMMERCIAL REFRIGERATION CONTROLS * Maritime models for use with corrosive media. ** Low-flow model.

Jul 9, 2015 ... R-410A AC Unit, Checking the Charge with Subcooling, Undercharged through Overcharged! AC Service Tech LLC•113K views · 4:22. Go to channel ...A refrigerator sealed system is a system in which refrigeration occurs. It is composed of the suction tube, metering device evaporator, condenser and compressor. The compressor inc...Refrigeration Research, Inc. is pleased to announce new, A.S.M.E. certified suction accumulators intended for use with R410A refrigerant. A.S.M.E. suction accumulators available in standard sizes and volumes, to make your transition to R410A as seamless as possible. All A.S.M.E. suction accumulators are finished with corrosion-resistant powder …For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 compressor can replace with R410A. by Mohammed Awais haji Latif.When it comes to choosing a hand held vacuum, there are several factors that determine its strength and effectiveness. From suction power to battery life, each feature plays a cruc...

The pressure of R-410A is so high that if your hand gets in the way of a leak, it could cut a finger off. This is a myth, as well as a physical impossibility. Devices such as insulin jet injectors require 7,000 to 10,000 psi pressures to puncture the skin and 16,000 to 25,000 psi pressure spikes are normally used.I have a 3 ton 410a Lennox with correct suction pressure however my high side pressure is way low. Pressures are 120headover 118 suction low side. What would be the cause. Bad txv or tev. On 2018-05-26 by (mod) - I might look for a thermostatic expansion valve that is not closing when it should or is not correctly adjusted.Typically, for a properly charged R-410A system, the low-side (suction) pressure may range from 120 to 150 psi, and the high-side (discharge) pressure may …Don't forget to LIKE,COMMENT SHARE & SUBSCRIBE ...Follow me on Facebook -https://www.facebook.com/musawfar/?mo...YouTube -https://www.youtube.com/channel/UCf...Continue the process until the system has been determined to be leak-free. Connect the vapor-line and liquid-line pressure taps to a vacuum pump and micron meter. This step is also almost always omitted. Evacuate the refrigerant lines and indoor coil to at least 350 microns. Close off the valve to the vacuum pump and observe the micron meter.1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction pressure normal head pressure.to adjust valves when facing adjusting stem clockwise decreases pressure / temperature. counter-clockwise increases pressure / temperature. rawal devices, inc. call tech support: (800) 727-6447 www.rawal.com ©2020 rawal devices, inc. doc#410a-sds

Let’s use the target superheat formula and calculate this manually: Target Superheat (R-410A) = (3 × 69°F – 80°F – 105°F) / 2 = 11.0°F. We see that the target superheat for R-410A refrigerant in this system is 11°F. You can use the target superheat calculator above to get to this result much quicker.psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F.A pressure mark is a sign of physical damage to the inside of an LCD screen. It is related to, but not always synonymous with, the problem of dead or stuck pixels. Usually it is no...Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ...Table of Contents. Refrigerant R-410A Pressure Temperature Chart - This R410A PT Chart will help you when charging a system that utilizes R-410A. Furthermore, R410A is an HFC and is commonly used in residential and light commercial HVAC equipment for air conditioners and heat pump systems.

Centurylink return label.

The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R-410A PT chart to adequately calculate the superheat, total superheat, and subcooling temperatures.Bags are hard to remove from garbage cans because of a vacuum that forms — until now. Expert Advice On Improving Your Home Videos Latest View All Guides Latest View All Radio Show ...Mar 26, 2024 · The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load. Mini Split 5/16 in. R410a Low Side Suction Charging Service Gauge Hose Set Port ... Low-side charging manifold with R410A low-side pressure gauge; View More Details; Store 0 in stock. Free & Easy Returns In Store or Online. Return this item within 90 days of purchase. Read Return Policy.Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Charge (limit) lbs 13 13 13 17 17 17 17 Oil Type Trane OIL00079 (qt)/OIL00080 (gal) Oil Charge oz 101 101 101 88 112 112 112 Suction Fitting Connection Brazed Brazed Brazed Brazed Brazed Brazed Brazed Suction Fitting (ODF) in 1.125 1.125 1.125 1.375 1.375 1.375 1.375In this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling. I go over the indicators of a Restriction such as vapor satur...

Sep 28, 2020 ... According to that outdoor temp the pressure will change alot. Your ... R-22 and R-410A Operating Pressures on Air Conditioners! Checking ...Jun 6, 2020 ... In this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling. I go over the indicators of a Restriction ...If you’re like 1 out of 3 Americans living with high blood pressure, then you and your doctor would probably be happy to see your blood pressure get lower. But is there such a thin...system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3.The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi. Vapor pressure: 295.5 psi. See all other pressures for R410 on …OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ...spring pressure calculation for R-410A (in SH) suction line temp PSI - sat. temp. PSI = spring pressure R410A (is in SH) when in doubt where do you mount the sensing valve?Temperature (°F): R410A Pressure (psig): -60 °F. 0.9 psig. -55 °F. 1.8 psig. -50 °F. 4.3 psig. What should be the 410a suction pressure? As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A. HFC-32 and HFC-125 are mixed together in R-410A, which is an azeotropic mixture. What is the r410a’s suction and discharge ... By contacting an HVAC technician, you can get your AC system’s suction pressure back to normal levels. If you are experiencing a problem with your air conditioning or heating call us at 512-336-1431 to schedule an appointment. We’ll be glad to come out and take a look at the issue. 1431-183 A/C & Heating proudly serves Round Rock ...Both suction and discharge pressure of R-410a systems are _____ than R-22 systems. Lower. Because of its higher vapor capacity, the discharge temperature of R-410a is _____ than R-22. 610 psig plus or minus 10psig. R-410a systems use a high pressure switch that will open at approximately: lose or gain.On a HFC-410A system, assume the suction pressure is 132 psig and the measured suction line temperature is 50F. The amount of superheat is. 2F. Which of the following is not required to determine the sub cooling for a system? Refrigerant saturation temperature.

This is where our friend R-410A came into play. New machines from 2010 and onwards were banned from using R-22. Instead, they were outfitted with R-410A. If you would like to read more about R-410A refrigerant please have a look at our Puron fact sheet. R-410A PT Chart. Let’s take a look at our pressure table for R-410A Puron.

I installed a new 410a complete system with new Orfice coil and new lineset. 70 degrees on install date and initial start up. Suction pressure was 110 and high side of 280. It ran for about 15 minutes. I added a little freon and the high side shot up to 425.Jan 16, 2023 · The temperature pressure charts in HVAC help in troubleshooting various problems with air conditioning systems such the the head and suction pressure, liquid lines and troubleshooting superheat and subcooling. Here are a few examples on using this chart. Example 1. What are the 410a pressures on a 85 degree day? Here are the steps to find the value Making changes to your diet is a proven way to help control high blood pressure. These changes can also help you lose weight and lower your chance of heart disease and stroke. Maki... Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:... In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera... Jun 24, 2020 · We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction pressure normal head pressure.

New hampshire liquor store portsmouth.

Ge.onehr.

What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system.Turn the thermostat to cool and set the target temperature at least 10 degrees lower than the indoor temperature. Let the system operate for at least 10 minutes to let pressures equalize. Record the suction line pressure. Use a temperature measuring device to measure the temperature of the suction line.On the other hand, a 5/8″ suction line on a 3.5 ton is “off the chart,” meaning it isn't acceptable under any conditions. Either way, our goal is to keep suction line pressure drop to a minimum while maintaining the minimum suction velocity, and this is the sweet spot manufacturers keep you in with these charts. #line sizing #suction line.Sep 11, 2021 ... Low Outdoor Temp, "CHECK THE REFRIGERANT CHARGE" in the Cold! · 64K views ; Charging R-410A Refrigerant into an Air Conditioner! Pressures, Temps,...In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...What should my normal operating pressures on 410a systems be? R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...Jul 16, 2021 · The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F. HVAC Technician: Mark Henley. Hi, Even with a different refrigerant you are still looking for the same coil temperature. So if you want a 40 degree indoor coil you will be at 120 PSI on the low side, then say you want a 100 degree condensing temperature ( 80 degree day ) you are looking for 320. The desired high side target pressure will change ...A pressure mark is a sign of physical damage to the inside of an LCD screen. It is related to, but not always synonymous with, the problem of dead or stuck pixels. Usually it is no...We would like to show you a description here but the site won’t allow us.Head pressure: 118F 83 + 35 = 118F more or less shows on the high side gauge if I understand this correctly. Low side pressure: 125 psi = 42 saturation temp. 66.2 low side line temp. High side pressure: 335psi = 104 saturation temp. 83.1 high side line temp. Temp at the vent in rooms: 56.1F + or minus. Temp from supply side: 55.2F. ….

Mini Split R410a Low Side Suction Charging Service Gauge Hose Set 5/16" Port. 91 Reviews. SKU: PGML-5/16B1/4Y. Free Shipping for Orders Above $49. Wholesale Price Directly From Factory. Secure and Versatile Payment Options. In stock, ready to ship. Price $35 52 $29 99 Save $5.53. Buy in monthly payments with Affirm on orders over $50.The liquid line pressure at 108°F saturation temperature is 356.5 PSIG. This screenshot of the Ref Tools app shows the liquid line pressure of R410A at saturation at 108°F. Notice how the slider has been set to BUBBLE point (inside the orange box). Vapor Line Pressure: Again, we already have the return air temp data, which is 74°F. liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressure The higher pressure, and the fact that R-410A performs very much like a single component refrigerant, provide an opportunity to produce a more compact system with greater efficiency. In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses. What is r410a’s suction pressure? When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22. Related Articles: Many women decide to live child-free. Yet, they often feel they owe everyone an explanation about a choice that should be entirely personal. OUR BRANDSTemperature (°F): R410A Pressure (psig): -60 °F. 0.9 psig. -55 °F. 1.8 psig. -50 °F. 4.3 psig. Freon™ 410A Rerierant Suction Line Size—Evaporator to Compressor (cont’d) –11 °F through –30 °F (37 through 19 psig) –31 °F through –50 °F (18 through 6 psig) Suggested Allowable Pressure Drop in psig = 2 °F 1.9 lb (2 °F) 1.3 lb (2 °F) Equivalent Suction Line Length—Feet System Capacity Btu/Hr System Capacity Currently working on a Bremar ice maker. Just did a compressor change and thought I weigh charged it perfectly. But it's not making good ice. I have only a suction port to read the pressures, and I'm getting 300kpa at the beginning of the 8.5 min cycle, and around 240kpa by the end. It runs for 8.5miutes then goes on defrost to drop the ice made. Suction pressure for 410a, Never install suction- line filter drier in the liquid- line of an R-410A system.! CAUTION 7. If suction-line filter drier was installed for system clean up, operate system for 10 hr. Monitor pressure drop across drier. If pressure drop exceeds 3 psig, replace suction-line and liquid-line filter driers. Be sure to purge system with dry nitrogen ..., Technical Guide: R-410A Outdoor Split- System Heat Pump - RHP143. York International Corporation, 5005 York Drive, Norman, OK 73069. 2022-10-05 6231804-UTG-A-1022 Supersedes: nothing. 2 Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 Johnson Controls Ducted Systems., psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114, Hence, R410A refrigerant is considered safer than R22 refrigerant which is why it is a direct replacement for R22 refrigerant despite being slightly higher in GWP. R410A refrigerant is also a high-pressure refrigerant. The suction pressure of R410A air conditioners is usually around 125 psi (862 kPa) which is much higher than R22 air …, Discharge line temperature 150°F (65°C) or higher at the end of the freeze cycle. Discharge line temperature less than 150°F (65°C) at the end of the freeze cycle or Compressor shell is frosted. Evaporator Outlet Temperature Comparison. Attach and insulate temperature probes between evaporator outlet and 90° elbow., R410A Pressure Temperature Chart R410A Temperature (°C) Pressure (barA) Pressure (barg) Pressure (psig) Pressure (barA) Pressure (barg) Pressure (psig)-70 0.36 -0.66 -9.52 0.35 -0.66 -9.55-68 0.40 -0.61 -8.85 0.40 -0.61 -8.87-66 0.45 -0.56 -8.10 0.45 -0.56 -8.13-64 0.51 -0.50 -7.27 0.51 -0.50 -7.31-62 0.57 -0.44 -6.37 0.57 -0.44 -6.40, AZ-20 (R-410A) pressure is about 60% (1.6 times) greater than R-22. Only use servicing equipment and components designed for AZ-20 (R-410A). – Recovery cylinder service pressure rating 400 psig, e.g. DOT 4BA400 and DOT BW400. – Manifold sets must be 800 psig high-side and 250 psig low-side with 550 psig low-side retard., What should my gauge readings be on 410a on 95 degrees at condenser. looking at pt chart at 95 degrees shows 295 is - Answered by a verified HVAC Technician. ... The liquid pressure should be 385-395 and the suction pressure should be about 138 but will probably be a few psi lower since it's so cool in the space. The sub …, The high side pressure, in contrast, refers to the refrigerant pressure in the discharge line. This is basically the pressure after the compressor. Even though the ideal pressure range for an R-401A air conditioner falls in the range of 110-140, its low side pressure should not be less than 100 psi, nor should it be more than 160 psi. Why this ... , The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to …, I am wondering what the high and low pressures should be in a 3-ton 410a refrigerant AC system. The installer seemed - Answered by a verified HVAC Technician ... .If the room was at 78 (round to 80) and if the coil was running 25 degrees colder (i.e. 55 degrees), we would see a suction pressure of 155 psig.Since the room was at 84 …, Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is _____ than R22, Both suction and discharge pressures of R-410A systems are _____ than R-22 systems, The temperature glide for R-410A is less than _____ degrees Fahrenheit over air conditioning and refrigerating operating ranges and more. , R-410A and R-22 is the higher operating pressures (approximately 50% higher on both the discharge side and the suction side).For example, a high-efficiency condensing unit using R-22 typically operates with a suction pressure of about 68 psi and a discharge pressure of about 250 psi at an outdoor temperature of 95°F., In this video, I show how a Liquid Line Restriction Affects The Liquid Pressure and Subcooling. I go over the indicators of a Restriction such as vapor satur..., Constants for vapor pressure of saturated vapor (dew point), p g: A = –1.440004 E+00 E = –3.521484 E+00 B = –6.865265 E+00 F = –7.750000 E+00 C = –5.354309 E–01 X o = 2.086902 E–01 D = –3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ..., The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ..., The vapor pressure of R-410A is almost 50% greater than R-22’s vapor pressure. New R-410A systems must be ... In addition, R-410A refrigerant allows more suction line pressure drop since it is less sensitive to suction line efficiency losses. The future of the HVAC & R market looks promising for the development and use of R-410A systems ..., pressure relief for R-410A will open at 550-625 psig. Suction and discharged pressure are 40% to 70% greater than R-22 and the discharge temperature of R-410A is lower due to its higher vapor heat capacity. Never heat an R-410A cylinder over 125ºF. • The high-pressure switch will open at 610 psig (plus or minus 10 psig), and, This script determines the gas pressure based on temperature of R410a refrigerant. R410A is an HFC refrigerant, invented by Honeywell, that has been developed to replace the HCFC refrigerant R22. Systems operating on R410A run at a pressure of about 1.6 times that of similar systems operating on R22. Energy efficiency is comparable to R22., This will allow you to measure the suction line temperature during the charging process. Step 2 – Taking Measurements Measure Suction Line Temperature. With your temperature probe in place, measure the ... Refer to a 410A pressure-temperature chart or use an HVAC app to convert the high-side pressure reading to the corresponding saturation ..., system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil. place an "x" on the appropriate chart where the suction and liquid pressures cross. if "x" is below ambient temperature line, add charge and repeat step 3., This is a table that tells you precisely what the pressure of R404A is at a certain temperature. At the low end, the pressure of 404A is 0.9 psig. At the high end, ... R410A PT Chart: -60°F To +155°F Pressure Temperature Chart; R22 PT Chart: Pressure Temperature Chart For -60°F To +155°F; R454B PT Chart: Pressures At -40°F To 150°F ..., Technical Guide: R-410A Outdoor Split- System Heat Pump - RHP143. York International Corporation, 5005 York Drive, Norman, OK 73069. 2022-10-05 6231804-UTG-A-1022 Supersedes: nothing. 2 Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 Johnson Controls Ducted Systems., If you don't mind getting your hands a little dirty, some petroleum jelly can increase the suction power of your plunger to help with particularly stubborn clogs. If you don't mind..., High Suction Pressure! I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and ..., suction pressure or too high discharge pressure. They can also be applied to start and stop compressors and the fans of air-cooled ... for high pressure refrigerants (R410A, R744) † Automatic, manual or convertible reset versions available † Vibration and shock resistant AI216886432210en-000901 Data Sheet, What Exactly is Suction Pressure? Suction pressure is the measure of how the refrigerant, particularly 404A, is drawn into the compressor. Imagine it as the “inhalation” phase of your cooler’s breathing process. It’s the starting point of the refrigeration cycle, setting the stage for everything that follows. 4. The Goldilocks Zone for 404A, Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so., Refrigerant Type R-410A R-410A R-410A R-410A R-410A R-410A R-410A Refrigerant Charge (limit) lbs 13 13 13 17 17 17 17 Oil Type Trane OIL00079 (qt)/OIL00080 (gal) Oil Charge oz 101 101 101 88 112 112 112 Suction Fitting Connection Brazed Brazed Brazed Brazed Brazed Brazed Brazed Suction Fitting (ODF) in 1.125 1.125 1.125 1.375 1.375 …, The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice., The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits., What should my normal operating pressures on 410a systems be? R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process., If you don't mind getting your hands a little dirty, some petroleum jelly can increase the suction power of your plunger to help with particularly stubborn clogs. If you don't mind...